- Manufacturer
- Low Voltage Switchgear and MCC
- Capitole 40 (IEC)
- Clink II (IEC)
- Halyester (IEC)
- Rawak
- Medium Voltage
- Xiria
- Power XPert UX
- Chalmit Lighting
- Abtech Junction Box
- BPG (Polyester)
- SX (Stainless / Mild Steel)
Capri Industry Atex Cable Glands
IEC and ATEX cable glands that are armoured and non-armoured. For use in flameproof, increased safety, or industrial applications.
-
ADE 1F
Expand / Close TabCable Gland Type
For unarmoured cable
Cable Type
Non-armoured cable or armoured cable(does not terminate the armour)
Certifications and Compliances
- ATEX LCIE 97 ATEX 6008X – Exd IIC /Exe II /Ex Td /Ex II 2 GD
- IECEx LCI 05.0004X
- cULus Listed for Class I Zone 2 AEx e II /Ex e II
- cULus Marine Listed for Class I Zone 1 AEx e II /Ex e II
- NEMA 4X and IP68
- CEPEL-EX-558/05X
- GOST-R P0CC FR.B02011
- NEPSI N° GYJ071336U & GYJ071337U
- ABS approbation: N°10-HS 577243-PDA / P 1836754-X
Features
- Standard material is nickel-plated brass for superior corrosion resistance
- Provides a weatherproof seal on the outer sheath of the cable
- Standard neoprene seal suitable for use in operation temperatures ATEX -60 to +100 Celsius
- Available with optional silicone seal for extreme temperatures
- Available with metric or NPT threads
-
ADE 4F
Expand / Close TabCable Gland Type
For armoured cable
Cable Type
Steel wire armoured cable, steel wire braided, steel tape armoured, braided marine shipboard and lead sheathed (with addition of earthing washer)
Certifications and Compliances
- ATEX LCIE 97 ATEX 6008X – Exd IIC /Exe II / Ex tD/ Ex II 2 GD
- IECx LCI 05.0004X
- cULus listed for Class I Zone 2 AEx e II /Ex e II
- cULus Marine listed for Class I Zone 1 AEx e II /Ex e II
- NEMA 4X and IP68
- CEPEL cepel-EX-559/05X
- GOST-R POCC FR.B02011
- NEPSI N°GYJ071336U & GYJ071337U
- ABS approbation: N°10-HS 577243-PDA / P 1836754-X
Features
- Standard material is nickel-plated brass for superior corrosion resistance
- Armour clamping and bonding with no reversible components for easy installation, minimizing error
- Provides flameproof seal on the outer sheath of the cable
- Standard neoprene seal suitable for use in operating temperatures ATEX -60°C to +100 °C
- Available with optional silicone seal for extreme temperatures
- Available with metric or NPT threads
-
ADE 6F
Expand / Close TabCable Gland Type
For armoured cable
Cable Type
Steel wire armoured cable, steel wire braided, steel tape armoured, braided marine shipboard
Certifications and Compliances
- ATEX LCIE 97 ATEX 6008X – Exd IIC /Exe II /Ex Td /Ex II 2 GD
- IECEx LCI 05.0004X
- cULus Listed for Class I Zone 2 AEx e II /Ex e II
- cULus Marine Listed for Class I Zone 1 AEx e II /Ex e II
- NEMA 4X and IP68
- CEPEL (pending)
- GOST-R P0CC FR.B02011
- NEPSI (pending)
- ABS approbation: N°10-HS 577243-PDA / P 1836754-X
Features
- Standard material is nickel-plated brass for superior corrosion resistance
- Armour clamping and bonding with no reversible components for easy installation & minimizing error
- Fully inspectable armour clamping and crimping including deluge boot
- Provides flameproof seal on inner sheath of cable
- Diaphragm seal for cold flow cables
- Provides a weatherproof seal of on the outer sheath of the cable
- Deluge boot provides enhanced protection from water ingress
- Standard neoprene seal suitable for use in operating temperatures ATEX -60°C to +100°C
- Available with metric or NPT threads
-
ADE 1FC
Expand / Close TabCable Gland Type
For unarmoured cable - Barrier gland
Cable Type
Non-armoured cable
Certifications and Compliances
- ATEX LCIE 97 ATEX 6008X – Exd IIC / Exe II/ Ex tD / Ex II 2 GD
- IECEx LCI 05.0004X
- NEMA 4X and IP68
- ABS approbation: N° 10-HS 577243-PDA / P 1836754-X
Features
- Standard material is nickel-plated brass for superior corrosion resistance
- Provides flameproof seal on the strands and the outer sheath of the unarmoured cables
- Signalitique: red cap nut
- Neoprene seal and resin certify in the range of temperature ATEX -60 °C to +80 °C
-
ADE 1FCC
Expand / Close TabCable Gland Type
For unarmoured cable - Barrier gland
Cable Type
Non-armoured cable
Certifications and Compliances
- ATEX LCIE 97 ATEX 6008X – Exd IIC / Exe II/ Ex tD / Ex II 2 GD
- IECEx LCI 05.0004X
- NEMA 4X and IP68
- ABS approbation: N° 10-HS 577243-PDA / P 1836754-X
Features
- Standard material is nickel-plated brass for superior corrosion resistance
- Provides flameproof seal on the strands and the outer sheath of the unarmoured cables
- Signalitique: red cap nut
- Provides the sealing on the external sheath of the not armed cables
- Neoprene seal and resin certify in the range of temperature ATEX -60 °C to +80 °C
- Available with metric or NPT threads
-
ADE 6FC
Expand / Close TabCable Gland Type
For armoured cable - Barrier gland
Cable Type
Steel wire armoured cable, steel wire braided, steel tape armoured, braided marine shipboard
Certifications and Compliances
- ATEX LCIE 97 ATEX 6008X – Exd IIC /Exe II /Ex Td /Ex II 2 GD
- IECEx LCI 05.0004X
- cULus Listed for Class I Zone 2 AEx e II /Ex e II
- cULus Marine Listed for Class I Zone 1 AEx e II /Ex e II
- NEMA 4X and IP68
- CEPEL (pending)
- GOST-R P0CC FR.B02011
- NEPSI (pending)
- ABS approbation: N°10-HS 577243-PDA / P 1836754-X
Features
- Standard material is nickel-plated brass for superior corrosion resistance
- Armour clamping and bonding with no reversible components for easy installation & minimizing error
- Fully inspectable armour clamping and crimping including deluge boot
- Provides flameproof seal on the strands and inner sheath of cable
- Provides sealing on the outer sheath of the armoured cables
- Signalitique: red cap nut
- Neoprene seal and resin certify in the range of temperature ATEX -60 °C to +80 °C
-
ADE 1FLC
Expand / Close TabCable Gland Type
For unarmoured cable
Cable Type
Non-armoured cable
Certifications and Compliances
- ATEX LCIE 97 ATEX 6008X – Exd IIC /Exe II /Ex Td /Ex II 2 GD
- IECEx LCI 05.0004X
- NEMA 4X and IP68
- ABS approbation: N°10-HS 577243-PDA / P 1836754-X
Features
- Standard material is nickel-plated brass for superior corrosion resistance
- Provides flameproof seal on the strands and t he outer sheath of the unarmoured cables li>Signalitique: red cap nut
- Neoprene seal and resin certify in the range of temperature ATEX -60°C to +80°C
-
ADE 6FLC
Expand / Close TabCable Gland Type
For armoured cable
Cable Type
Steel wire armoured cable, steel wire braided, steel tape armoured, braided marine shipboard
Certifications and Compliances
- ATEX LCIE 97 ATEX 6008X – Exd IIC /Exe II /Ex Td /Ex II 2 GD
- IECEx LCI 05.0004X
- NEMA 4X and IP68
- CEPEL cepel-EX-558/05X (pending)
- GOST-R P0CC FR.B02011 (pending)
- ABS approbation: N°10-HS 577243-PDA / P 1836754-X
Features
- Standard material is nickel-plated brass for superior corrosion resistance
- Resumption of armour without reversible components
- Provides flameproof seal on the bits and the inner sheath of the armoured cables
- Fully inspectable armour clamping and crimping including deluge boot
- Signalitique: red stopping plug
- Neoprene seal and resin certify in the range of temperature ATEX -60°C to +80°C
-
NEWCAP MS
Expand / Close TabCable Gland Type
For unarmoured or braided cable
Certifications and Compliances
- ATEX/Exe II/Ex tD/ Ex II 2 GD
- EN 50262
Features
- Material: Nickel-plated brass
- Neoprene sealing ring and dust cover
- Polyamide clamping bush
- Operating temperature range ATEX: -40°C +100°C
- O-ring
- IP 68: Protection according to NF EN 60529
- Metric thread: ISO-NF EN 60423 and NF EN 50262
-
NEWCAP CT
Expand / Close TabCable Gland Type
For round cable
Cable Gland Type
Unarmoured or braided cable
Certifications and Compliances
- ATEX/Exe II/Ex tD/ Ex II 2 GD
- EN 50262
Features
- Material: Nickel-plated brass
- Neoprene sealing ring and dust cover
- Polyamide clamping bush
- Operating temperature range ATEX: -40°C +100°C
- O-ring
- IP 68: Protection according to NF EN 60529
- Metric thread: ISO-NF EN 60423 and NF EN 50262
-
ECDEP Ex-e
Expand / Close TabCable Gland Type
For round cable
Cable Gland Type
Unarmoured round cable
Certifications and Compliances
- ATEX LCIE 97 ATEX 6007X /Exe II/Ex tD/ Ex II 2 GD
- EN 50262
Features
- Material: polyamide 6 – UL 94 halogene free
- Color: black RAL 9005
- Santoprene seal ring
- Operating temperature range ATEX: -20°C + 80°C
- IP 68 according to NF EN 60529
- Metric thread: ISO-NF EN 60423 and NF EN 50262
-
ECDEP Ex-i
Expand / Close TabCable Gland Type
For round cable
Cable Gland Type
Unarmoured round cable
Certifications and Compliances
- ATEX LCIE 97 ATEX 6007X /Exe II/Ex tD/ Ex II 2 GD
- EN 50262
Features
- Material: polyamide 6 – UL 94 halogene free
- Colour: black RAL 9005 – blue RAL 5012 (capnut)
- Santoprene seal ring
- Operating temperature range ATEX: -20°C + 80°C
- IP 68 according to NF EN 60529
- Metric thread: ISO-NF EN 60423 and NF EN 50262
-
ADE 1
Expand / Close TabCable Gland Type
For armoured cable
Cable Type
Steel wire armoured cable, steel wire braided, steel tape armoured, braided marine shipboard and lead sheathed (with addition of earthling washer)
Features
- Standard material is nickel-plated brass for superior corrosion resistance
- Armour clamping and bonding with no reversible components for easy installation, minimizing error
- Provides the sealing on the inner and outer sheath of the armoured cables
- Continuous use temperature: 20°C to +100°C
- Available with metric or NPT threads